Main text

Nichols AL, Blumenfeld Z, Fan C, Luebbert L, Blom AEM, Cohen BN, Marvin JS, Borden PM, Kim CH, Muthusamy AK, Shivange AV, Knox HJ, Campello HR, Wang JH, Dougherty DA, Looger LL, Gallagher T, Rees DC, Lester HA. 2022. Fluorescence activation mechanism and imaging of drug permeation with new sensors for smoking-cessation ligands. eLife 11:e74648. doi: 10.7554/eLife.74648.

Published 4 January 2022

We now correct an error in Figure 1. “Revision 0” of the paper, submitted on 8 November 2021 and reviewed by the Reviewers 1, 2, and 3, contained the intended, correct version of Figure 1:

However, the authors made a mistake on “Revision #1”, submitted 30 December 2012 and accepted on 3 January 2022. In that mistake, Figure 1 Panel E2 was duplicated from Figure Panel E1. This mistaken duplication in Panel E2 was part of the originally published version, shown here for reference:

Also, we now correct calculation and presentation errors in the stopped-flow data reported in Figure 5 and in Supplementary File 2.

In Figure 5, the corrected legend for panels (A – D) lists the [drug] values after mixing in the stopped-flow chamber. There was no need to correct the calculations and curve fits (Vmax and Kd values) for panels 5E, F, and G.

In addition, the corrected Figure 5G now includes the previously omitted 10-fluorocytisine point at 500 μM.

The stopped-flow experiments for iCyt_BrEt_SnFR at 31.25 μM and 7.8 μM had different sampling rates than all other measurements. The corrected Figure 5H now presents corrected kobs values for these measurements, leading to corrected, fitted Vmax and Kd for iCyt_BrEt_SnFR.

The corrected Figure 5:

The originally published Figure 5 is shown here for reference:

The corrected caption for Figure 5 should now read:

Figure 5. Stopped-flow fluorescence kinetic data for (A) iDianiSnFR, (B) iCytSnFR, (C) iCyt_F_SnFR, and (D) iCyt_BrEt_SnFR over 1 s and 100 s.

Fluorescence was activated by mixing with the agonists, producing the indicated final concentrations. Stopped-flow data show a departure from first-order kinetics for this set of iDrugSnFRs. iDianiSnFR and iCyt_F_SnFR are fitted to a double exponential; iCytSnFR and iCyt_BrEt_SnFR are fitted to a single exponential. (E-H) Plots of the observed apparent rate constant kobs against [agonist] for the 1 s data obtained in (A-D).

The original caption for Figure 5 is shown for reference:

Figure 5. Stopped-flow fluorescence kinetic data for (A) iDianiSnFR, (B) iCytSnFR, (C) iCyt_F_SnFR, and (D) iCyt_BrEt_SnFR over 1 s and 100 s.

Fluorescence was activated by mixing with the agonists as noted. Stopped-flow data shows a departure from first-order kinetics for this set of intensity-based drug-sensing fluorescent reporter (iDrugSnFRs). iDianiSnFR and iCyt_F_SnFR are fit to a double exponential; iCytSnFR and iCyt_BrEt_SnFR are fit to a single exponential. (E–H) Plots of the observed apparent rate constant against [agonist] for the 1 s data obtained in (A–D). In (H), we have confidence that the kobs shows a maximal value of 40–50 s–1; the Kd probably lies within twofold of the fitted value.

The corrected caption for Figure 5 removes an ambiguity about the final concentrations. The corrected caption for Figure 5 also removes the final sentence of the original version; this final sentence, which implied uncertainties in the fitted curves, is inappropriate in view of the corrected sampling rate.

The corrected Supplementary File 2 now includes the corrected calculations and presentations described above. The corrected Supplementary File 2 omits kobs values for the lowest concentrations (0.245 μM) of iDianiSnFR and iCyt_F_SnFR; these traces were too noisy for systematic analysis.

We apologize to eLife readers, editors, and publication staff for these burdensome corrections. The corrections do not affect the paper’s major or minor conclusions. The corrections do not affect the detailed kinetic analysis of cytisine kinetics in Appendix 2.

Article and author information

Author details

  1. Annet EM Blom

  2. Bruce N Cohen

  3. Jonathan S Marvin

  4. Philip M Borden

  5. Charlene H Kim

  6. Anand K Muthusamy

  7. Hailey J Knox

  8. Hugo Rego Campello

  9. Jonathan H Wang

  10. Dennis A Dougherty

  11. Loren L Looger

  12. Timothy Gallagher

Version history

  1. Version of Record published: December 15, 2022 (version 1)

Copyright

© 2022, Nichols et al.

This article is distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use and redistribution provided that the original author and source are credited.

Metrics

  • 191
    Page views
  • 1
    Citations

Article citation count generated by polling the highest count across the following sources: Crossref, PubMed Central, Scopus.

Download links

A two-part list of links to download the article, or parts of the article, in various formats.

Open citations (links to open the citations from this article in various online reference manager services)

Cite this article (links to download the citations from this article in formats compatible with various reference manager tools)

  1. Aaron L Nichols
  2. Zack Blumenfeld
  3. Chengcheng Fan
  4. Laura Luebbert
  5. Annet EM Blom
  6. Bruce N Cohen
  7. Jonathan S Marvin
  8. Philip M Borden
  9. Charlene H Kim
  10. Anand K Muthusamy
  11. Amol V Shivange
  12. Hailey J Knox
  13. Hugo Rego Campello
  14. Jonathan H Wang
  15. Dennis A Dougherty
  16. Loren L Looger
  17. Timothy Gallagher
  18. Douglas C Rees
  19. Henry A Lester
(2022)
Correction: Fluorescence activation mechanism and imaging of drug permeation with new sensors for smoking-cessation ligands
eLife 11:e85479.
https://doi.org/10.7554/eLife.85479

Share this article

https://doi.org/10.7554/eLife.85479