Abstract
Quantifying the complexity of neural activity has provided fundamental insights into cognition, consciousness, and clinical conditions. However, the most widely used approach to estimate the complexity of neural dynamics, Lempel-Ziv complexity (LZ), has fundamental limitations that substantially restrict its domain of applicability. In this article we leverage the information-theoretic foundations of LZ to overcome these limitations by introducing a complexity estimator based on state-space models —which we dub Complexity via State-space Entropy Rate (CSER). While having a performance equivalent to LZ in discriminating states of consciousness, CSER boasts two crucial advantages: 1) CSER offers a principled decomposition into spectral components, which allows us to rigorously investigate the relationship between complexity and spectral power; and 2) CSER provides a temporal resolution two orders of magnitude better than LZ, which allows complexity analyses of e.g. event-locked neural signals. As a proof of principle, we use MEG, EEG and ECoG datasets of humans and monkeys to show that CSER identifies the gamma band as the main driver of complexity changes across states of consciousness; and reveals early entropy increases that precede the standard ERP in an auditory mismatch negativity paradigm by approximately 20ms. Overall, by overcoming the main limitations of LZ and substantially extending its range of applicability, CSER opens the door to novel investigations on the fine-grained spectral and temporal structure of the signal complexity associated with cognitive processes and conscious states.
Introduction
Complexity measures in neuroscience
Since the advent of complexity science, there has been great interest in its application to understand the brain (Turkheimer et al., 2022). Lempel and Ziv’s now-classical complexity measure (Lempel and Ziv, 1976) has been highly influential and widely applied in the neuroimaging literature, especially for the neuroscientific study of consciousness. LZ complexity is a simple scalar metric that has been consistently shown to be a robust indicator of depth of anaesthesia (Zhang et al., 2001), disorders of consciousness (Casali et al., 2013), sleep (Abásolo et al., 2015; Schartner et al., 2017b), and, more recently, the psychedelic state (Schartner et al., 2017a; Timmermann et al., 2019; Mediano et al., 2020b), making it one of the most effective known functional markers of conscious state in humans. LZ is also effective as a biomarker of mental disorders such as schizophrenia (Ibáñez-Molina et al., 2018; Rajpal et al., 2022) and depression (Bachmann et al., 2015; Akar et al., 2015), as well as tracking fluctuations of normal wakefulness related to drowsiness (Mediano et al., 2021), mind wandering (Ibáñez-Molina and Iglesias-Parro, 2014), or artistic improvisation (Dolan et al., 2018).
Despite its practical effectiveness and widespread use, LZ has longstanding limitations that severely restrict its domain of applicability. First, the application of LZ requires that the data be discretised, which loses information and introduces artificial non-linearities (Ibáñez-Molina et al., 2015; Yeh and Shi, 2018). Second, the LZ algorithm needs to be provided with relatively large windows of data (on the order of a few seconds for typical EEG data), which limits its temporal resolution —making it impossible to do complexity analyses of non-stationary data, such as the fast time-locked neural events studied with ERP signals. Third, it is not possible to do a principled spectral decomposition of LZ, a fundamental obstacle to our understanding of the relationship between complexity and power spectrum —which is highly relevant in neuroscience as electrophysiological signals are often differently distributed across several frequency bands.
In this paper we introduce a novel approach to calculate an LZ-style complexity that overcomes all these limitations. To do so, our approach builds on the rich literature of state-space models, powerful and versatile statistical time series models widely used in neuroscience and beyond (Durbin and Koopman, 2012). Our method, which we call Complexity via State-space Entropy Rate (CSER), solves all of LZ’s above-mentioned issues:
CSER does not require the signal to be discretized, allowing it to fully exploit continuous signals and avoiding potential artefacts introduced by the discretization procedure.
CSER allows instantaneous (i.e. sample-by-sample) estimation, bringing complexity analyses to the realm of event-related paradigms.
CSER has a principled spectral decomposition, closing the gap between complexity and traditional spectral analyses.
In the rest of the paper, we first describe the basic intuitions behind the common use of LZ in neuroscience. We then introduce our estimator, CSER, and discuss its tight mathematical links with signal diversity and prediction error (Den Ouden et al., 2012). Next, we showcase CSER’s properties in a comparison of different states of consciousness and in data from an auditory mismatch negativity paradigm. Finally, we conclude with a discussion on how to interpret complexity measures applied to neural activity, and note on the applicability of CSER to other neuroimaging modalities.
Complexity and entropy rate
Before we delve into the formulation of our new estimator and the new results obtained with it, it is worth examining the theoretical foundations of LZ as a measure of complexity.
The informational content of a discrete signal 𝒳 = (X1, X2, …) at time t can be quantified by its entropy,
which can be seen as measuring the difficulty of guessing the signal’s value at that point in time—the more difficult this is, the more information one gains by learning the signal’s actual value. If the signal preferentially takes some specific values, then the signal is easier to predict, which corresponds to a low entropy. On the other hand, if the signal takes all of its available values with similar frequency (i.e. its histogram is nearly flat), then there is high uncertainty about its current value and hence observing it will be very informative, which corresponds to a case of high entropy.
Crucially, entropy only takes into account the relative frequency of values, but not the order in which they appear. As an example, consider a signal A corresponding to the sequence 01010101, and a signal B, corresponding to the sequence 01110010. A naive plug-in estimator (Panzeri et al., 2007) applied to these signals would yield the same entropy for both, as they have the same frequency of 0s and 1s. However, if one knows the past trajectory of the sequence it is clearly much easier to predict the next value of signal A than signal B. This aspect of a signal’s unpredictability —the difficulty of predicting the next value after knowing all previous ones —is quantified by the signal’s entropy rate, here denoted by h(𝒳). In the above example, signals A and B have the same entropy, but signal A has lower entropy rate than B. In other words, entropy is invariant to reshuffling the order of elements in a sequence, whereas entropy rate is not —making the latter a more appropriate measure of dynamical complexity.
Estimating entropy rate in practice from limited data is, however, a challenging task. This is due to several factors, most prominently the “curse of dimensionality” (Paninski, 2003). This is where the LZ algorithm comes into play.
In essence, the original algorithm by Lempel and Ziv (1976) breaks up a signal into patterns, and uses the number of distinct patterns to quantify the complexity of that signal. Regular sequences with repeating patterns have low LZ, and rich signals with many patterns have high LZ. A fundamental result by Ziv (1978) shows that this number of patterns can be used to efficiently estimate the entropy rate of the process that generated the data. Specifically, given a discrete stochastic process1 𝒳= (X1, X2, …, XT) with LZ complexity c(𝒳), its entropy rate can be estimated as2
Furthermore, the concept of entropy rate allows us to draw a direct connection between the common interpretation of LZ as signal diversity and another important framework in neuroscience: predictive processing. In essence, the more diverse a signal is, the higher the prediction error one would incur when trying to forecast its future (see Methods for details).
In this work, we provide evidence that the empirical successes of LZ can be linked directly to the underlying and more general mathematical construct of entropy rate. This opens a way to formulate metrics, based on entropy rate, that are similar to LZ in spirit but do not suffer from the same limitations —as we showcase in the remainder of this article.
Results
Having outlined the core principles behind LZ, and also having described its inherent limitations, we can now introduce our novel estimator, CSER. We demonstrate that CSER preserves the utility of LZ while offering multiple clear advantages over it, illustrated across three sets of results. First, we show that CSER preserves the valuable empirical effectiveness of LZ, and can clearly discriminate between states of consciousness, in different species and different neuroimaging modalities. Then, we illustrate two examples of new analysis methods that can be performed by leveraging the advantageous properties of state-space models, which are not possible with LZ: spectral and temporal decomposition of entropy in neural signals. Mathematical details of CSER and validation analyses on artificial data can be found in the Methods section.
Estimating entropy rate via state-space models
The core principle of state-space analysis is to assume that the observed data, 𝒳, can be modelled as noisy observations of a hidden process 𝒵 that is not accessible to direct measurement (Fig. 1). Mathematically, a state-space model is fully specified by two ingredients: the dynamics of the hidden state 𝒵 (horizontal arrows); and the observation process that relates 𝒵 with the observed data 𝒳 (vertical arrows). A simple yet effective choice is to assume that both the dynamics and observation processes are linear and normally distributed. Fitting a state-space model, then, corresponds to finding the linear coefficients and covariance matrices that best describe the relationship between zt and zt+1, and between zt and xt (see Methods for more details).
The properties of state-space models make it straightforward to calculate entropy rate from a fitted model. In particular, the key property of state-space models is that the hidden state zt con-tains all the relevant information about x1 …, xt−1 needed to predict xt. Then, thanks to the assump-tion of normality and the link between entropyrate and prediction error, entropy rate can be cal-culated with the usual formula of the entropy of a Gaussian distribution (Cover and Thomas, 2006, Sec. 8.4) —resulting in the CSER estimator. See the Methods section for details on state-space models, model selection, and the robustness of CSER to model misspecification.
Discriminative power between states of consciousness
The main feature that makes LZ complexity interesting for neuroscientists is its empirical predictive value: for instance, it consistently decreases in states of loss of consciousness such as sleep or general anaesthesia (Zhang et al., 1999; Casali et al., 2013; Varley et al., 2020);3 and increases in states with richer subjective contents of consciousness like the psychedelic state (Schartner et al., 2017a; Mediano et al., 2020b). Therefore, one would expect that any candidate competing measure of complexity should preserve those desirable empirical properties.
To comprehensively validate this hypothesis, we analyse data of subjects in different well-defined states of consciousness obtained through different neuroimaging modalities. In particular, we use three datasets:
MEG data from 15 human subjects under the effects of the psychedelic drug LSD, as well as a placebo (PLA) (Carhart-Harris et al., 2016).
EEG data from 9 human subjects in dreamless NREM sleep, as well as a wakeful rest baseline (Wong et al., 2020).
ECoG data from 4 macaque subjects under the effects of ketamine and medetomidine (KTMD) anaesthesia, as well as a wakeful rest baseline (Yanagawa et al., 2013).
In all cases, we compute CSER and LZ (for comparison) for each channel separately following the procedure outlined in the Methods section, and report results averaged across all channels (Fig. 2). Results show that CSER fully agrees with LZ, increasing in subjects under the effects of LSD, and decreasing in subjects in NREM sleep or general anaesthesia. The effects have the same sign for LZ and CSER across all three datasets, and are significant with p < 0.001 for the psychedelics and sleep datasets, and with p < 0.05 for the anaesthesia dataset (details in Supplementary Table 1). Furthermore, the spatial distributions across the brain for LZ and CSER show qualitative agreement, especially for the modalities with good spatial resolution (MEG and ECoG). These results confirm that CSER is able to perform the same discriminatory role as LZ on a wide range of datasets and states. We next highlight two clear advantages of using CSER instead of LZ: spectral decomposition and temporal resolution.
Spectral decomposition of entropy changes
Given the increasing prominence of LZ analyses in neuroscience, multiple efforts have been made to elucidate whether, and to what extent, changes in LZ across states of consciousness relate to neural activity in different frequency bands (Schartner et al., 2017b; Boncompte et al., 2021). Answering this question, however, requires sophisticated surrogate data tests (Mediano et al., 2020a), and definite answers are yet to be established.
In contrast, the relation between linear models and spectral decomposition is well known (Hannan and Deistler, 2012), which allows us to perform an exact, analytical decomposition of the entropy rate into frequency components (see Methods for details). Therefore, one can split the complexity of a signal into different frequency bands, with the guarantee that the terms associated with bands that cover the whole spectrum will sum up to the broadband CSER. This allows us to properly interpret their relative and absolute magnitudes, and to attribute changes in entropy rate between conditions to a particular band in a principled manner.4
As a proof of concept, we applied this spectral decomposition to the three datasets used in the previous section using the standard partition of the spectrum into frequency bands (Fig. 3). Given the guarantee that differences in all spectral components sum up to the total difference, we can conclude that the changes in complexity across states of consciousness are mainly driven (in absolute magnitude) by high-frequency neural activity.
Our results provide formal validation of the long-standing hypotheses linking high-frequency and non-rhythmic signals to consciousness. Gamma oscillations were at the center of early consciousness work by Crick and Koch (1990),5 and have been posited as the neural underpinning of self-awareness (Lou et al., 2017). They also align with more recent evidence showing the power of gamma activity in discriminating between states of consciousness (Walter and Hinterberger, 2022), as well as with results by Canales-Johnson et al. (2019) showing that it is broadband (rather than rhythmic) components that encode prediction errors, which in turn have been put forward as a tool to understand conscious contents (Hohwy and Seth, 2020). However, we emphasise that our results are distinct from the known results of decreased gamma coherence with loss of consciousness (e.g. Cavinato et al., 2015) —even when controlled for average gamma coherence, differences in CSER between conscious states remain qualitatively unchanged (Supp. Table 3).
Interestingly, CSER’s ability to decompose the complexity of a signal into frequency bands can give us new insights by effectively providing more “dimensions” to study the complexity of neural data. As an example, note that in the comparison between LSD and placebo (Fig. 3, left), all bands except gamma actually have a small, but significant, negative change in CSER, opposite to the overall trend. Future research should disentangle the mechanistic origins of these different complexity changes, and explore if they have different effects on behaviour and subjective experience.
Temporally-resolved entropy measures
So far, LZ has been considered a measure of state —i.e. a property of the typical dynamics observed in the resting-state spontaneous neural activity of a subject. A few recent studies have attempted to capture a more fine-grained temporal evolution of LZ, typically by using a sliding window, although such approaches suffer from a trade-off between time-resolution and estimation noise. Hence, this method only works when the process under consideration has comparatively slow dynamics.6
This limitation of seeing LZ only as a “state measure” is caused, at least in part, by the requirement of large sequence lengths for enabling a robust estimation (a few thousand samples, or several seconds for EEG; c.f. Fig. 5). However, leveraging the explicit parametric form of the state-space models that CSER is based on, we can formulate an instantaneous entropy rate that provides an analogue of LZ computable for each time point in multi-trial data.
To illustrate this powerful capability of CSER, we analyse ECoG data from macaque monkeys undergoing an auditory oddball task (Komatsu et al., 2015). The auditory oddball is a passive listening task in which monkeys listen to one of two stimuli: a ‘standard’ tone which is consistent with prior expectation, and a ‘deviant’ tone which isn’t (Fig. 4, left). One of the most characteristic and widely studied phenomena related to this task is the presence of a mismatch negativity (MMN) reponse in the event-related potential (ERP): a strong negative peak following the deviant stimulus (Fig. 4, top right). The MMN occurs approximately 50 to 100 ms post-stimulus in marmosets (Komatsu et al., 2015) and 150 to 250 ms in humans (Näätänen et al., 2007), and has been studied in a wide variety of experimental settings.
Importantly, one of the leading theories of the mechanisms behind MMN describes it as representing a violation of the brain’s predictions of incoming sensory signals —in essence, when processing the deviant stimulus the brain incurs a ‘prediction error’ that results in stronger activity (Garrido et al., 2009). Given that higher entropy rate is directly linked with a larger prediction error (see Methods), we hypothesised that the deviant stimulus would also elicit an increase in entropy rate (with respect to the standard stimulus) as measured by CSER.
To study the time-resolved entropy rate of this data, we employed the following procedure:
i) Fit a state-space model to the baseline pre-stimulus data, obtaining a set of model parameters.
ii) Use the obtained parameters to evaluate the model and make one-step-ahead predictions in standard and deviant time series, estimating the residual time series.
With the estimated residuals and the known baseline residual variance we can compute a local (i.e. instantaneous) entropy rate, analogous to the model prediction error at time t (see Methods and Appendix for details). Using this method, we can compare the instantaneous entropy during the course of standard and deviant percepts in the macaque ECoG, and compare them to the known ERP traces (Fig. 4, right).
In agreement with our predictions, deviant stimuli induce a significant increase in prediction error (and thus, entropy rate) with respect to standard stimuli. Furthermore, and perhaps more interestingly, the peak difference in instantaneous entropy rate precedes the ERP peak by approximately 20 ms. We speculate that this highly temporally localised entropy peak could represent the onset of the prediction error itself, that steers neural dynamics in different trajectories depending on the nature of the stimulus, while the difference in neural activity (i.e. ERP amplitude) reflects the spontaneous evolution of these two trajectories.7 Naturally, we do not make strong generalisation claims for this phenomenon based on a single subject, although we believe these results warrant further study of the temporal entropy profile of other prediction error-related tasks.
Discussion
Electrophysiological data such as EEG, MEG and ECoG, have as their main advantage over other brain-scanning techniques, such as fMRI, that they provide temporally rich information about neuronal activity in different frequency bands. Over the last two decades, the most common method to examine the complexity of these signals has been Lempel-Ziv complexity (LZ), which can be seen as an estimator of the information-theoretic concept of entropy rate. Despite the remarkable practical efficacy of LZ, it is —by construction —unable to give information about the temporal or spectral distribution of this complexity.
The present work introduces a new information-theoretic tool to cognitive neuroscience, CSER, which has distinct advantages over LZ. First, we have shown that CSER has substantially better temporal resolution compared to LZ and is highly sensitive to changes in cognitive state on a mismatched negativity task, potentially detecting a cognitively important neural signal before standard ERPs do. Second, unlike LZ, CSER naturally provides a principled spectral decomposition, yielding intriguing insights about the relationship between gamma-band activity and changes in conscious state.
Across species and imaging modalities, we demonstrate the ability of CSER to provide information about both of these aspects, which LZ could simply not provide. These results may serve as a proof of concept, opening the door to a wide range of new investigations of spectral and temporal aspects of neural complexity observed on multiple kinds of neuroimaging data in cognitive and consciousness studies.
Advantages and limitations of state-space models in neuroimaging
Throughout this paper we have showcased the power of state-space time series models for a variety of neuroimaging data analyses. Our choice of state-space as models is due to their generality and flexibility, since i) they are easy to use and estimate, and do not require discretising the data, ii) they are robust to noise and misspecifications in the fitting process, and iii) they are able to model and account for a variety of noise factors common in neural data.8
Furthermore, the rich analysis possibilities enabled by state-space modelling (as evidenced by the spectral and temporal decompositions above) enable us to explore new dimensions describing the complexity of neural dynamics —which could possibly be mapped to different aspects of consciousness and cognition (Luppi et al., 2021). Additionally, the possibility of having sample-by-sample entropy rate estimates allows for the application of multiple analysis techniques from the field of local information dynamics, such as instantaneous information transfer (Lizier, 2010) or integrated information (Mediano et al., 2022). Conceptually, one could see the generation of entropy rate time series from data as a transformation “from volts to bits,” opening the door to new analyses on entropy time-series complementary to those on conventional ERPs. We believe these techniques could reveal new information about neural processes and could be a fruitful avenue of future research.
At the same time, however, there are some specific circumstances where state-space models need to be applied with care. Two of these are i) applications to fMRI data, and ii) M/EEG data after ICA component removal (or average re-referencing). In the case of fMRI, the problem can be related to the haemodynamic response filter, which may introduce singularities in the data (Solo, 2016),9 and may be alleviated by restricting the maximum model order and regression horizon hyperparameters during the fitting process (see Methods for details). When dealing with preprocessed M/EEG data, ICA component removal may reduce the rank of the data and incur numerical errors when fitting a single state-space model to large sets of channels. In this case, one could mitigate the problem by fitting separate models to smaller subsets of channels, reducing the regression horizon, or adding a very small amount of white noise to the data.
Finally, note that state-space models are not the only alternative to LZ to estimate entropy rate: there exist other parametric methods, such as auto-regressive models (Barnett and Seth, 2014), as well as non-parametric methods, such as spectral factorisation (Chand and Dhamala, 2014). Nonetheless, state-space models remain our model of choice due to their greater tractability and flexibility, which makes them readily usable in most neuroscientific contexts. It is also pos-sible to build more sophisticated state-space modes, e.g. by combining them with multi-taper techniques (Kim et al., 2018).
Concluding remarks
In this paper we have presented a new method, which we call Complexity via State-space Entropy Rate (CSER), as a principled estimator of signal diversity for electrophysiological time series. We have shown that CSER has the desirable empirical properties of successful complexity measures, like Lempel-Ziv complexity, while substantially extending Lempel-Ziv’s capabilities in several ways. Combining four datasets comprising three distinct neuroimaging modalities, several states of consciousness, and an auditory task, we have shown that CSER is a valuable analysis tool that can provide spectrally and temporally resolved insights that were previously impossible —in the first case showing that the difference in complexity across states of consciousness is attributable to high-frequency activity; and in the latter, showing that instantaneous complexity peaks before the standard ERP signature of mismatch negativity. To make this method widely available for the neuroscience community, we provide an open-source implementation of CSER and other entropy rate estimators for several programming languages in https://www.github.com/pmediano/EntRate.
Overall, these results emphasise the neuroscientific value of a principled information-theoretic approach, helping us distil the key properties of known methods while empowering neuroscientists to investigate previously inaccessible dimensions of their data.
Methods
Datasets and preprocessing
In order to benchmark CSER against LZ, we decided to include data spanning both i) multiple neuroimaging modalities, and ii) a wide range of states of consciousness. With this in mind, the results in Figs. 2 and 3 were obtained with the following data:
Psychedelics
We use the MEG data first reported by Carhart-Harris et al. (2016) of N = 15 subjects after an infusion of intravenous LSD (or a placebo). Data were source-reconstructed to the centroids of each region in the Automated Anatomical Labelling (AAL) atlas (Tzourio-Mazoyer et al., 2002) using a standard LCMV beamformer. For a full description of the source-reconstruction pipeline see Mediano et al. (2020b).
NREM sleep
We used the EEG data of N = 9 subjects during sleep, some of which were previously reported by Wong et al. (2020). Although the original study focused on the neurophysiology of dreams, here we used only segments of data from dreamless NREM sleep, and compared it against a wakeful rest baseline.
Anaesthesia
We used the ECoG data of N = 4 marmoset monkeys sedated with KTMD anaesthesia first reported by Yanagawa et al. (2013). Data were obtained from the open access Neurotycho database and divided into ‘awake’ and ‘sedated’ periods.
For all datasets, in addition to modality-specific cleaning, we filtered the data using a lowpass filter with a 100 Hz cutoff, removed line noise by subtracting a least-squares-fit sinusoidal signal at 50 Hz and harmonics, and downsampled it to 200 Hz. For both LZ and CSER, we segmented the data into pseudo-stationary epochs, computed LZ and CSER for each epoch and channel (sources in the LSD dataset, electrodes in the others), and averaged across all epochs and channels. To compute LZ, each epoch was further detrended and binarised around its mean.
Finally, for the time-resolved analysis of an auditory oddball paradigm we use data previously presented by Komatsu et al. (2015). We used only data from the monkey Fr, since it is the only one publicly available in the NeuroTycho website. Given that ECoG data is typically less corrupted by noise, and that for the analysis in Fig. 4 we were interested in the fine temporal structure of the process, we relaxed the lowpass filter to 150 Hz and the downsampling to 300 Hz.
The two faces of LZ: signal diversity and intrinsic prediction error
Mathematically, the entropy rate of a stochastic process 𝒳 is defined as the asymptotic rate of growth of its entropy, i.e.
This expression refers to the joint entropy of full trajectories (X1, …, XT), denoted by H(X1, …, XT). This quantity is related to how much the signal is exploring possible paths: the number of trajectories of T time-steps that are effectively visited by the system is approximately 2T h(𝒳).10 Hence, for sequences built on K different symbols, the signal is exploring a fraction 2h(𝒳)/K of the space of possible configurations. These results give the basis for a rigorous interpretation of LZ as signal diversity: a higher LZ implies that the system explores a larger fraction of its possible trajectories.
On the other hand, standard results in information theory (Cover and Thomas, 2006, Th. 4.2.1) state that the entropy rate can also be expressed as the entropy of the present state conditioned on its past:
i.e. the uncertainty in the moment-to-moment prediction of the next state of the system. In Gaussian systems this corresponds to the logarithm of the mean squared error (Cover and Thomas, 2006), and in discrete systems it is related to the probability of misclassification (Fano, 1961; Feder and Merhav, 1994). Thus, entropy rate is also formally linked with intrinsic prediction error:11 a higher LZ value means it is harder to predict the next value of the signal —even with complete knowledge of its past trajectory.
Therefore, thanks to information theory and the concept of entropy rate we can bridge between two previously disconnected interpretations of complexity in neural dynamics: signal diversity and prediction error. We believe rigorous investigation of the mathematics underlying analysis frameworks can lead to more convergence between neuroscientific theories (Rosas et al., 2020; Luppi et al., 2020), and is a worthwhile avenue for future research.
Model description and entropy rate estimation
Consider data generated by a stationary, real-valued, discrete-time d-dimensional stochastic process , and T ∈ ℕ. The core principle of state-space (SS) modelling is to assume that 𝒳 can be modelled as noisy observations of an m-dimensional hidden process , with yt ∈ ℝm. Hence, the model is determined by two ingredients: the dynamics of the hidden process 𝒴, and the measurement function that relates 𝒴 with 𝒳. A simple and effective family of models are those with linear dynamics and normally distributed error terms,
where A ∈ ℝm×m is the state transition matrix, C ∈ ℝ d×m is the observation matrix, and ut, vt are zeromean white noise processes with covariance matrices , and .
We calculate the entropy rate of 𝒳 by representing the above SS model in innovations form. For this, we consider “innovations” of the form , and define , where is a shorthand notation for the past trajectory of 𝒳. Then, one can show that the innovations are noise-like, zero-mean i.i.d. variables with covariance .Then, the above SS model can be re-written as
where K is typically referred to as the Kalman gain matrix. This is a standard result in time series analysis —for a proof see e.g. Durbin and Koopman (2012, Sec 4.3). With these relationships, one can show that
where the first equality follows from the fact that (by definition) 𝓏t is a deterministic function of , and the second equality from the fact that forms a Markov chain. This equation shows one of the key properties of (innovations form) state-space models: that the hidden state 𝓏t encapsulates all the knowledge about the signal xt one can acquire up to time t − 1. Using this, one can plug Eq. (7) into the expression of entropy rate in Eq. (4), and find that
As a final step, given that the innovations are normally distributed, one can compute the entropy rate of 𝒳 using the standard formula for Gaussian distributions (Cover and Thomas, 2006, Sec. 8.4):
Importantly, before fitting the model and computing CSER we normalise the signals to unit variance. This makes the results invariant to measurement units, prevents biases stemming from differences in total power between two conditions, and allows us to interpret CSER as a function of the proportion of signal variance that is not explained by the past of the signal itself.
It is also worth noting CSER can take negative values. This is because, unlike LZ, CSER estimates the entropy rate of a real-valued distribution (technically called a differential entropy rate; Cover and Thomas, 2006). Although differential entropy rates can be negative, their interpretation is the same as their discrete counterpart: higher entropy implies more randomness and less predictability.
In summary, state-space models reduce the daunting task of estimating the entropy rate of the observed process to the estimation the innovations covariance Σ. As we show below, this can be done efficiently with off-the-shelf software, resulting in a flexible, multi-purpose complexity estimator.
Model selection, convergence speed, and robustness
Given its focus on state-space models, it is no surprise that the core of the CSER computation lies on estimating the SS parameters themselves. To this end, we use the state-space subspace (SS-SS) algorithm by Van Overschee and De Moor (2012). There are two parameters we need to specify to run the SS-SS algorithm: the past and future regression horizons (p, J), and the model order m. Here we present our method for estimating the horizon and model order parameters, without describing the SS-SS algorithm in detail —see Van Overschee and De Moor (2012) for further details.
First, following Bauer (2001), we set the regression horizon using the estimated model order q of an AR model, which we fit with the LWR algorithm (Morf et al., 1978). We then use the Hannan-Quinn information criterion (Hannan and Quinn, 1979) to select the optimal AR order qHQC, and set P = f = 2qHQC. Finally, using these horizons we use the singular value criterion by Bauer (2001) to obtain the optimal state-space model order m. This protocol can be implemented with the MVGC toolbox (Barnett and Seth, 2014), and results in a method that is flexible, automated, and applicable to various types of data.
To test this procedure, we generated synthetic data from a set of univariate auto-regressive models of order q with varying residual variance, and compared the ground-truth entropy rate values with the CSER estimates. We simulated time series of varying length from each model, and computed CSER with the procedure outlined above (Fig. 5, right). For comparison, we did a similar analysis with LZ: we generated synthetic binary data of Markov order q (i.e. where xt is a random boolean function of xt−1, …, xt−q with added noise), and estimated their entropy rate with LZ (Fig. 5, left).
The results show CSER’s clear advantages over LZ as an entropy rate estimator: it is unbiased even for relatively short time series, and variances vanish for longer time series. Even for highly autocorrelated data the variance in CSER drops for time series longer than 103 samples —well within reach of common M/EEG datasets. LZ, in contrast, takes orders of magnitude more samples to converge, especially for time series with long memory (which is the case in most neural data modalities).
On a separate front, one natural question that arises is whether a misestimation of model order m may lead to an erroneous estimation of entropy. To address this, we perform a similar test: first, we write an SS model of known order with fixed A, C, K parameters; then, we randomly sample a residual covariance matrix from an exponential distribution and simulate the resulting SS model; and finally, we estimate its entropy rate with models of lower order (Fig. 6).
These results again highlight the robustness of the CSER estimator: even when the model order is severely underestimated, CSER is still able to recover the entropy rate of the underlying generative process with high accuracy. Furthermore, CSER is also able to recover the original power spectrum, even if the incorrect model order is used —although it should be noted that if the model order is significantly underestimated the spectrum estimation may suffer.
Spectral decomposition of CSER
The core element of our spectral entropy rate decomposition is the following expression relating the residual variance and the spectral density of a stationary process, which we state here without proof (Hannan and Deistler, 2012, Th. 1.3.2):
Given the simple expression of the entropy rate in Eq. (9), it is straightforward to re-write the above equation into a spectral decomposition of entropy rate (Chicharro, 2011). We do this by adding d log(2πe) to both sides and using the fact that xt is real-valued (and thus (ω) = (−ω)):
With this expression at hand, we only need to compute the spectral density S(ω) of the process from the parameters of the state-space model. This is a standard result (Hannan and Deistler, 2012), although we rehearse it here for completeness.
We begin by defining L as the backshift operator, such that Lzt = zt−1. With it, we can rewrite Eq. (6a) as zt = Azt−1 + Kct−1 = AL t + KLct. Solving for zt and substituting in Eq. (6b) we obtain the expression of the transfer function of the process, here denoted12 by M(L), as
which allows us to write the MA representation of xt as a convolution over a white noise process, xt = M(L) * ϵt. Now we can simply use the fact that the Fourier transform of a convolution is the product of the Fourier transforms, and arrive at the expression of the spectral density as a function of the transfer function and the residuals’ variance:
Putting everything together, to compute the results in Fig. 3 we compute the spectral density using Eq. (13) by evaluating Eq. (12) at ei w, and finally integrate Eq. (11) numerically using the desired (normalised) frequency band as limits for the definite integral.
Temporally resolved entropy rate
We model the response to the auditory stimulus as a perturbation to an otherwise stationary state-space model. In a nutshell, our method consists of i) train a single state-space model using the pre-stimulus baseline of all trials; ii) use the trained model to compute prediction errors post-stimulus; and iii) compute the log-likelihood of the prediction errors. In the following we describe this procedure in detail. See the Appendix for a technical discussion and validation of this modelling choice.
Recall the ECoG data used here has 720 standard and 720 deviant trials. To train the model, we extract the pre-stimulus baseline (−400 to 0 ms w.r.t. stimulus presentation), stack all 1440 trials together, and train a single state-space model using the model selection procedure described above. This yields a set of (A, C, K, I-) parameters, which we leave fixed for the rest of the analysis. Then, for every trial we compute the residuals by performing one-step-ahead predictions —i.e. running the Kalman filter algorithm with fixed parameters (Durbin and Koopman, 2012, Sec. 4.3). We compute the residuals for the whole duration of the trial (−400 to 400 ms w.r.t. stimulus presentation), resulting in empirical prediction errors , where t denotes the time index and k the trial number.
Next, we average the prediction errors across trials as , where the average is taken over the standard and the deviant trials separately, resulting in two time series and respectively. Finally, using the fact that are i.i.d., we know that e t ∼ 𝒩 (0, I-/ R), where R is the number of trials averaged, so we can compute their log-likelihood as ht = log 𝒩; (et| 0, I-/R). The difference corresponds to the blue curve in Fig. 4.
To determine the statistical significance of the results, we perform a nonparametric cluster test following Maris and Oostenveld (2007). To do this we obtain surrogate samples of by randomly shuffing the trial labels. We follow the same process to compute surrogate values, against which we compare the observed Δht values to obtain a statistic suitable for the cluster test.
Acknowledgements
PM and DB were funded by the Wellcome Trust (grant no. 210920/Z/18/Z). FR was supported by the Fellowship Programme of the Institute of Cultural and Creative Industries of the University of Kent. AIL is funded by the Gates Cambridge Trust (OPP 1144). AKS and LB are supported by European Research Council Grant ERC-AdG-CONSCIOUS, project number 101019254, to AKS.
Appendix Supplementary tables
In this appendix we report the full statistical analysis (mean, standard deviation, Cohen’s d, t-score and -value) of subject-level differences across states of consciousness. Tables 1 and 2 correspond to the analyses shown in Figures 2 and 3, respectively.
Appendix LZ is a measure of entropy, not algorithmic complexity
A significant portion of the neuroscience literature that employs LZ argues that it is somewhat akin to the Kolmogorov-Chaitin algorithmic complexity (Sitt et al., 2014; Casali et al., 2013). This is by no means an unmotivated belief, as the original ideas of Lempel and Ziv were certainly motivated by Kolmogorov’s work (Lempel and Ziv, 1976), and well-known references promote the use of LZ as an upper bound to Kolmogorov-Chaitin algorithmic complexity (Li et al., 2008). Although this is not technically incorrect, in what follows we argue that this can lead to undesirable misinterpretations.
Recent investigations have shown that, despite superficial similarities, Shannon’s entropy and algorithmic complexity are fully dissociated (Zenil et al., 2019). In particular, while Shannon’s entropy can always be used as upper bound of the algorithmic complexity, this bound can be infinitely inaccurate.13 Furthermore, there is reason to be skeptical of alleged estimators of algorithmic complexity from experimental data. Kolmogorov’s Invariance (or Universality) Theorem states that the Kolmogorov complexity of a sequence x read with two different Turing machines differs by a constant independent of x (Cover and Thomas, 2006, Ch. 14). An important corollary for practical applications is that said constant can be arbitrarily large for any finite sequence. For practical purposes, that means that a measured difference between two conditions may be a genuine difference in algorithmic complexity, or may just be a Turing machine mismatch —which has a substantially different interpretation. This is not to say that algorithmic complexity cannot be estimated from data —see e.g. Zenil et al. (2018) –, although there is great nuance involved which cannot be simply swept under the rug of the LZ algorithm.
In addition to the concerns above, there is one more hurdle to the Kolmogorov complexity interpretation of LZ: it relies on the fundamental assumption that the sequence must be exactly reproduced by a Turing machine (Cover and Thomas, 2006). This is a very strong assumption to make regarding neural dynamics, which clashes with contemporary accounts of the brain as a nonlinear stochastic system (Deco et al., 2009). For these reasons, we believe the interpretation of LZ as entropy rate is both more mathematically principled and more parsimonious, and thus should be preferred when interpreting empirical results.
Appendix Alternatives for entropy estimation in non-stationary data
In general, modelling of ERPs is a difficult task due to the strongly non-stationary nature of event-related data (Ding et al., 2000). As mentioned in the Methods section, the time-resolved entropy analysis shown in Fig. 4 was performed assuming a constant model subject to a non-stationary perturbation. For completeness, here we discuss an alternative approach: one could leverage the trial structure of the data by fitting SS models using all trials and sliding temporal windows, and computing CSER for each of them.
In essence, the approach used in the main text corresponds to modelling the ERP as nonstationary innovations in a stationary model, and the approach introduced here corresponds to stationary innovations in a non-stationary model. In principle, these two alternatives can be pitted against each other through standard model selection tests, e.g. via a likelihood ratio test. However, the likelihood function of a non-stationary state-space model is complicated, and therefore this approach is difficult in practice.
Nonetheless, as an example of this approach and as a validation of the approach from the main text, we performed a sliding-window CSER analysis on the same oddball task data as before. For this, we processed the data following recommendations by Ding et al. (2000) (including time-wise ensemble demeaning and normalisation) and computed CSER in sliding windows of 20 samples. We performed this analysis both with and without filtering and downsampling, to obtain a more granular picture of the CSER time-course (Fig. 7).
The most visible result from this analysis is that indeed there is temporal structure in the sliding-window CSER across the trial, most noticeably a sharp dip around the stimulus time. This could be interpreted as the stimulus dominating the signal and suppressing endogenous noise; or, in more cognitive terms, as there being some uncertainty about the precise stimulus timing which is resolved as soon as the stimulus is presented.
Strictly speaking, this means the assumptions behind the model from Fig. 4 are not fully correct, since at least one parameter (Σ) changes over the course of the trial. However, when comparing the standard and deviant CSER values, there are no significant differences between the two types of stimuli surviving a cluster test (Maris and Oostenveld, 2007). Therefore, although it does seem likely that model parameters change throughout the course of the trial, this change does not account for the difference between stimuli found in Fig. 4.
To summarise, we have described two different ways in which a time-resolved entropy rate time course can be obtained from multi-trial data leveraging state-space models. These make different assumptions, and although they are difficult to test rigorously, they may have different advantages in different situations.
References
- Lempel-Ziv complexity of cortical activity during sleep and waking in ratsJournal of neurophysiology 113:2742–2752
- Nonlinear analysis of EEGs of patients with major depression during different emotional statesComputers in Biology and Medicine 67:49–60
- Lempel Ziv complexity of EEG in depressionIn: 6th European Conference of the International Federation for Medical and Biological Engineering Springer :58–61
- The MVGC multivariate Granger causality toolbox: A new approach to Granger-causal inferenceJournal of Neuroscience Methods 223:50–68
- Granger causality for state-space modelsPhysical Review E 91
- Detectability of Granger causality for subsampled continuous-time neurophysiological processesJournal of Neuroscience Methods 275:93–121
- Order estimation for subspace methodsAutomatica 37:1561–1573
- Brain activity complexity has a nonlinear relation to the level of propofol sedationBritish Journal of Anaesthesia 127:254–263
- Broadband Signal Rather than Frequency-Speci1c Rhythms Underlies Prediction Error in the Primate Auditory CortexBioRxiv
- Neural correlates of the LSD experience revealed by multimodal neuroimagingProceedings of the National Academy of Sciences 113:4853–4858
- A theoretically based index of consciousness independent of sensory processing and behaviorScience Translational Medicine 5:198–198
- Coherence and consciousness: Study of fronto-parietal gamma synchrony in patients with disorders of consciousnessBrain Topography 28:570–579
- Spectral factorization-based current source density analysis of ongoing neural oscillationsJournal of Neuroscience Methods 224:58–65
- On the spectral formulation of Granger causalityBiological Cybernetics 105:331–347
- Elements of Information TheoryHoboken: Wiley
- Towards a neurobiological theory of consciousnessIn: Seminars in the Neurosciences 2
- Stochastic dynamics as a principle of brain functionProgress in Neurobiology 88:1–16
- How prediction errors shape perception, attention, and motivationFrontiers in Psychology 3
- Short-window spectral analysis of cortical event-related potentials by adaptive multivariate autoregressive modeling: Data preprocessing, model validation, and variability assessmentBiological Cybernetics 83:35–45
- The improvisational state of mind: A multidisciplinary study of an improvisatory approach to classical music repertoire performanceFrontiers in Psychology 9
- Time Series Analysis by State Space MethodsOxford University Press
- Transmission of Information: A Statistical Theory of CommunicationMIT Press
- Relations between entropy and error probabilityIEEE Transactions on Information Theory 40:259–266
- A regression framework for effect size assessments in longitudinal modeling of group differencesReview of General Psychology 17:111–121
- The mismatch negativity: A review of underlying mechanismsClinical Neurophysiology 120:453–463
- The determination of the order of an autoregressionJournal of the Royal Statistical Society: Series B (Methodological) 41:190–195
- The Statistical Theory of Linear SystemsSIAM
- Predictive processing as a systematic basis for identifying the neural correlates of consciousnessPhilosophy and the Mind Sciences 1
- Fractal characterization of internally and externally generated conscious experiencesBrain and cognition 87:69–75
- Multiscale Lempel–Ziv complexity for EEG measuresClinical Neurophysiology 126:541–548
- EEG multiscale complexity in schizophrenia during picture namingFrontiers in physiology 9
- State-space multitaper time-frequency analysisProceedings of the National Academy of Sciences 115:E5–E14
- Mismatch negativity in common marmosets: Whole-cortical recordings with multi-channel electrocorticogramsScienti1c Reports 5:1–7
- On the complexity of 1nite sequencesIEEE Transactions on Information Theory 22:75–81
- An introduction to Kolmogorov complexity and its applicationsSpringer
- The Local Information Dynamics of Distributed Computation in Complex SystemsPhD thesis, University of Sydney
- Towards a cognitive neuroscience of self-awarenessNeuroscience & Biobehavioral Reviews 83:765–773
- A synergistic workspace for human consciousness revealed by integrated information decompositionBioRxiv
- What it is like to be a bit: An integrated information decomposition account of emergent mental phenomenaNeuroscience of Consciousness 2021
- Nonparametric statistical testing of EEG- and MEG-dataJournal of Neuroscience Methods 164:177–190
- Fluctuations in neural complexity during wakefulness relate to conscious level and cognitionbioRxiv
- Decomposing spectral and phasic differences in non-linear features between datasetsarXiv
- Integrated information as a common signature of dynamical and information-processing complexityChaos: An Interdisciplinary Journal of Nonlinear Science 32
- Effects of external stimulation on psychedelic state neurodynamicsbioRxiv
- Recursive multichannel maximum entropy spectral estimationIEEE Transactions on Geoscience Electronics 16:85–94
- The mismatch negativity (MMN) in basic research of central auditory processing: A reviewClinical Neurophysiology 118:2544–2590
- FieldTrip: Open Source Software for Advanced Analysis of MEG, EEG, and Invasive Electrophysiological DataComputational Intelligence and Neuroscience 1:1–1
- Level of consciousness is dissociable from electroencephalographic measures of cortical connectivity, slow oscillations, and complexityJournal of Neuroscience 40:605–618
- Estimation of entropy and mutual informationNeural Computation 15:1191–1253
- Correcting for the sampling bias problem in spike train information measuresJournal of Neurophysiology 98:1064–1072
- Psychedelics and schizophrenia: Distinct alterations to Bayesian inferencebioRxiv
- Reconciling emergences: An information-theoretic approach to identify causal emergence in multivariate dataPLoS Computational Biology 16
- Increased spontaneous MEG signal diversity for psychoactive doses of ketamine, LSD and psilocybinScienti1c Reports 7
- Global and local complexity of intracranial EEG decreases during NREM sleepNeuroscience of Consciousness 1
- Large scale screening of neural signatures of consciousness in patients in a vegetative or minimally conscious stateBrain 137:2258–2270
- State-space analysis of Granger-Geweke causality measures with application to fMRINeural Computation 28:914–949
- Neural correlates of the DMT experience assessed with multivariate EEGScienti1c Reports 9:1–13
- A complex systems perspective on neuroimaging studies of behavior and its disordersThe Neuroscientist 28:382–399
- Automated anatomical labeling of activations in SPM using a macroscopic anatomical parcellation of the MNI MRI single-subject brainNeuroimage 15:273–289
- Subspace Identi1cation for Linear Systems: Theory, Implementation, ApplicationsSpringer Science & Business Media
- Consciousness & brain functional complexity in propofol anaesthesiaScienti1c Reports 10:1–13
- Determining states of consciousness in the electroencephalogram based on spectral, complexity, and criticality featuresNeuroscience of Consciousness 2022
- The Dream Catcher experiment: Blinded analyses failed to detect markers of dreaming consciousness in EEG spectral powerNeuroscience of Consciousness 2020
- Large-scale information 2ow in conscious and unconscious states: An ECoG study in monkeysPloS ONE 8
- Generalized multiscale Lempel–Ziv complexity of cyclic alternating pattern during sleepNonlinear Dynamics 93:1899–1910
- A decomposition method for global evaluation of Shannon entropy and local estimations of algorithmic complexityEntropy 20
- An algorithmic information calculus for causal discovery and reprogramming systemsiScience 19:1160–1172
- EEG complexity as a measure of depth of anesthesia for patientsIEEE transactions on Biomedical Engineering 48:1424–1433
- Detecting ventricular tachycardia and 1brillation by complexity measureIEEE Transactions on Biomedical Engineering 46:548–555
- Coding theorems for individual sequencesIEEE Transactions on Information Theory
Article and author information
Author information
Version history
- Preprint posted:
- Sent for peer review:
- Reviewed Preprint version 1:
Copyright
© 2023, Mediano et al.
This article is distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use and redistribution provided that the original author and source are credited.
Metrics
- views
- 479
- downloads
- 33
- citations
- 2
Views, downloads and citations are aggregated across all versions of this paper published by eLife.