Published measurements of specific loss power (SLP) for various magnetic particles of diameter d, taken at a magnetic field strength H and frequency f. The values in the column “SLP corr” are corrected for the field and frequency used by Stanley et al. (2015).

DOI: http://dx.doi.org/10.7554/eLife.17210.005

ReferenceMateriald
[nm]
H
[kA/m]
f
[kHz]
SLP
[W/g]
SLP corr [W/g]Notes
Fortin et al. (2007)Fe2O35.324.870042.8
Fortin et al. (2007)Fe2O36.724.87001410
Fortin et al. (2007)Fe2O3824.87003726
Fantechi et al. (2015)Fe3O48121836.575
Hergt et al. (2004)Fe2O37154101549
Fantechi et al. (2014)ferritin with Fe3O4612.4183<0.01<0.1per mass of only the metal ions
Fantechi et al. (2014)ferritin with Co0.15Fe2.85O46.812.41832.8130per mass of only the metal ions